Product > Wall panels

STT Türk Gazbeton Horizontal Wall Panels are Reinforced Wall Elements that may be used on interior and exterior walls of any concrete, steel, wooden and prefabricated structure. These panels can be applied by being assembled between columns as well as on their interior and exterior surfaces. This property of Horizontal Wall Panels enables diverse architectural facades with different functions and preferences. They can be easily and rapidly assembled by means of assembly apparatuses and crane. Reinforced Wall Elements are designed and produced in such a way to endure different wind and earthquake forces to which they might be exposed.

Horizontal Wall Panels
Standard Dimensions
Length (l) ≤600 cm
Width (b) ≤60 cm
Thickness (d) 10-30 cm
Physical Properties

Physical Properties

Material Durability Class G3 G4 Unit
Average Compressive Strength 35 50 kgf/cm2
Maximum Dry Density Interval 500 600 kg/m3
Elasticity Module 17500 22500 kgf/cm2
Thermal Conductivity λd* 0.14 0.16 W/mK
λh* 0.13 0.16
Static Calculation 620 720 kg/m3
Safety Coefficient 1.9
Water Vapor Diffusion Resistance Factor 5-10
גd : True heat conductivity of the material measured under laboratory conditions.
Load-Bearing Vertical Wall Panels

STT Türk Gazbeton Vertical Wall Panels can be produced as load-bearing in order to be used in masonry constructions. These panels can be used as interior and exterior walls in such constructions. Even in the most risky places defined as first-degree seismic zones in Disaster Regulation, it is possible to build masonry constructions up to two floors by using Load-Bearing Wall Panels.

Vertical Wall Panels
Standard Dimensions
Length (l)≤600 cm
Width (b)≤60 cm
Thickness (d)10-30 cm
Physical Properties

Physical Properties

Material Durability ClassG3G4Unit
Average Compressive Strength3550kgf/cm2
Maximum Dry Density Interval500600kg/m3
Elasticity Module1750022500kgf/cm2
Thermal Conductivityגd*0.140.16W/mK
 גh*0.130.16
Static Calculation620720kgf/cm3
Water Vapor Diffusion Resistance Factor5-10
Safety Coefficient1.9
גd : True heat conductivity of the material measured under laboratory conditions.